Screen shots from one of the systems operating in Mittal Steel Poland,
Unit in Dąbrowa Górnicza,
Former Huta Katowice


Laser measurement system next to gag press

Rails with the straightness defects have to be repaired - straightened on the gag press. GRAW offers also systems that can operate with gag presses. Rail profiles are displayed on the gag press operator's screen, making it possible to position the rail exactly in reference to the actual positions of the press anvils. Once the press actuator straightens the rail in some place, this part of the rail profile is marked red (see below) as no longer valid. Therefore, the operator knows what parts of the rail have already been subjected to the repair. At any time he or she is free to verify the effect of the straightening operation by measuring the rail again.